No spark, no warning, and the part is already damaged

About half of all ESD damage is latent, the part survives the line and fails in the field. That kind of defect never traces back.

ESD

01Where static comes from

When two materials touch and separate, electrons move from one to the other, triboelectric charging. The triboelectric series sets the direction: skin, glass and nylon tend positive; PTFE, PVC and silicone tend negative.

Motion10 – 20% RH65 – 90% RH
Walking across carpet35,000 V1,500 V
Walking on vinyl flooring12,000 V250 V
Rising from a work chair18,000 V1,500 V
Picking a PE bag off the bench20,000 V1,200 V
Peeling tape off a rollover 15,000 Va few thousand V
Figures follow the ESD Association's commonly cited comparison. Humidity is one of the cheapest and most effective variables you control.

02Three discharge models

ModelFull nameScenario
HBMHuman body modelA charged person touches the part. The most common case.
MMMachine modelA charged metal fixture or piece of equipment touches the part
CDMCharged device modelThe part itself is charged and touches ground. Extremely fast discharge.
A CDM event lasts only nanoseconds and carries the highest peak current, which makes it the main threat on automated lines.

03EPA: the ESD protected area

The core idea in IEC 61340-5-1 is the ESD protected area, a zone where every conductor, people included, is bonded to the same ground reference so no potential difference exists between them.

  • Wrist straps. The primary way to ground a person, with a 1 MΩ resistor in series to limit current. Test them at the start of every shift.
  • ESD bench and floor matting. Surface resistance of 10⁶ to 10⁹ Ω, too low is a shock hazard, too high does not dissipate.
  • ESD footwear and flooring. How you ground standing or moving operators.
  • Ionizers. They handle charge on insulators, plastic housings, tape and packaging cannot be grounded, only neutralized.
  • Packaging. Conductive (black), shielding (silver) and dissipative (pink) bags all serve different purposes; only a shielding bag blocks an external field.

04Humidity and environment

Higher relative humidity forms a thin film of moisture on surfaces, raising surface conductivity so charge bleeds away on its own. The usual recommendation for an EPA is 40 to 60% RH:

  • Below 30%: static risk climbs sharply.
  • Above 70%: metal parts and PCBs risk oxidation and condensation.

05How you prove it works

ItemFrequencyTool
Wrist strap functionEvery shift startWrist strap tester
Bench / floor mat surface resistanceQuarterlySurface resistance meter
Ionizer balance voltageQuarterlyCharged plate monitor (within ±35 V)
EPA ground resistanceAnnuallyGround resistance tester
Charge on people and toolsSpot checksNon-contact electrostatic fieldmeter
An ESD program with no measurement records is, to a customer auditor, a program that does not exist.